MCO-230AIC

770(W) x 730(D) x 905(H) mm
230 liters (8.1 cu.Ft.)
Ambient temperature: +5°C to 50°C
LOADING.....
상품이미지 최대 사이즈
  • 상품이미지 1
  • HMS
  • GOOGLE PLUS
상품 정보 표
판매가격 1
제조사/원산지 PANASONIC/일본
  • - +
    1원 X
총 합계금액 1
  • 상품상세설명
  • 고객상품평
  • 상품문의
  • 배송/취소/교환안내

상품상세설명

카다로그 PDF 다운로드

Features

파나소닉 유일의 H2O2오염제거 시스템채용의 CO2 인큐베이터

LCD TouchPanel Controller

A WVGA color LCD touchpanel delivers full controlover different protocols. Standard USB port provids convenient log data transfer

image
*IData log period is 1.5 months using 2-minute intervals.
*Password protected USB memories cannot be used.
*Multiple detailed activity logs exported to indivisual CSV files.
image
Security

Automatic door locking (electric lock) can be set on the MCO-170AICUVH (standard equipped) and other models equipped with the optional electric lock (MCO-170EL).

Control Panel with single‒user Key Lock (MCO-170AIC/MCO-230AIC), Addition of user ID function for better traceablilty (able to register up to 99 user-IDs and passwords)(MCO-230AIC)

image
The Auto-Lock set up screen
image
Password input window
image
Key Lock set up screen
image
Single-user with Key Lock

Tray catches are integral parts of the chamber, opening up more space for trays, allowing the incubator to accommodate more culture containers.

Comparison with MCO-20AIC
image
Integrated Tray catches(Comparison with MCO-19AIC)
image

Rapid, Effective and Safe An industry-first. Panasonic’s Cycle

unique high-speed system utilizing vaporized H2O2 offers time-saving and documented chamber decontamination with complete safety.

* Attaching the optional MCO-170HB and MCO-170EL to MCO-230AICUV will add the H2O2 decontamination function.

  • Full decontamination process takes less than three hours, saving valuable time. For example, if the decontamination cycle is started at 9 am, the unit will be ready for use in the afternoon.
image
CurrentTraditional
MCO-230AIC
MCO-230AIC
SafeCell UV Decontamination
  • SafeCell UV includes a programmable ultraviolet lamp, isolated from cell cultures, that decontaminates conditioned air and humidity reservoir water to prevent contamination without affecting cell cultures in vitro.
  • Contaminants trapped within the humidifying pan at the base of the plenum are destroyed by high intensity, ozone-free ultraviolet light.
  • Decontaminated, humidified air is released from the lower plenum for vertical convection through and around the perforated shelves. Interior air motion is suspended when the door is opened, minimizing movement of room air contaminants into the chamber. The unique air duct system also improves temperature recovery characteristics.
Airflow and water pan decontamination using a UV system

Specfications

ModelMCO-230AICUVH
External Dimensions770 x 730 x 905 (mm) / 30.3 x 28.7 x 35.6 (inch)
Interior Dimensions490 x 523 x 665 (mm) /19.3 x 20.6 x 26.2 (inch)
Interior Volume230 liters (8.1 cu.Ft.)
Data AcquisitionAutomatic log function of temperature, CO2, Door opening/closing, Alarm and CSV file output
Exterior Cabinet and DoorGalvanized steel with baked-on finish
Interior and ShelvesCopper-enriched stainless steel
Outer DoorGalvanized steel with baked-on finishReversible heated
Inner DoorTempered glass
ShelvesCopper-enriched stainless steel 4 supplies as standard (Maximum 10), Exterior dimensions: 620 (W) x 450 (D) x 12 (H) mm, maximum load 7kg/shelf, Adjustable
Access PortDiameter 30mm port with non-VOC silicone stoppers (1 on back side)
InsulationExtruded polystyrene foam
Heating Method-
Air FlowGentle vertical airflow, continuous with inner door closed
Air Filter0.3μm, Effeciency:99.97% or higher (for CO2)
UV Lamp-
Water Level Sensor-
CommunicationRemote alarm contacts standard. Optional 4-20mA connection. Optional with RS-232C/ RS-485/LAN data ports
CO2 Gas Connection4mm to 6mm inner diameter tubing
CO2 Gas Pressure0.03 MPa (G) (0.3Kgf/cm2G, 4.3psiG) from two stage CO2 regulator
Net Weight90kg (176 lbs)
Tempearture Control Range+5°C above ambient to 50 °C*1 (Ambient temperature: 5°C-35°C)
Tempearture Uniformity±0.25°C (23°C ambient, setting: 37°C, CO2: 5%, no load)*2
CO2 Control Range and Deviation0% to 20%,±0.15% (23°C ambient, setting 37°C, 5% CO2, no load)
Interior Humidity95% ±5%R.H. at 37°C by natural evaporation with humidifying pan
Max. Power Consumption440W
Max. Heat Discharge1250kJ/h
CO2 Sensor PlatformCeramic based, single beam infrared sensor, with dual wavelength measurement for continuous auto-zero calibration
CO2 Sampling Patent PendingNo moving parts; airflow passess over in/out ports to sustain continuous sampling
Leveling Feet4
CO2 Calibration-
  • *1 When ambient temperature is 25°C, temperature control range: 30°C∼50°C. Regardless of ambient temperature, the maximum of temperature control range is always 50°C.
  • *2 The measurement condition complies with Panasonic specified measuring method.
  • *3 Exterior dimensions of main cabinet only. See dimension drawings showing handles and other external projections.

고객 상품평

0개가 있습니다.

상품을 구매하신 회원님께서는 상품평을 작성해주세요. 상품평 작성하기

등록 된 상품평이 존재하지 않습니다.

상품문의

0개가 있습니다.

상품과 관련된 문의를 남겨주시면 답변을 드립니다. 상품 문의하기

등록 된 상품문의가 존재하지 않습니다.

배송/취소/교환안내

재고가 있는 제품의 경우, 평일 오후 4시 이전 결제 완료시 당일 출고됩니다.
배송까지는 택배사의 상황에 따라 1~2일 이상 소요될 수 있습니다.
판매금액 기준 100,000원 이상부터 무료  배송입니다.
교환 및 반품을 위해서는 왕복택배비 6,000원을 동봉하여 거래명세표와 함께 물건을 보내주시기 바랍니다.
자세한 문의는 고객센터 02-508-1408로 전화 부탁드립니다.



배송정보
배송조회를 하시려면 송장번호를 클릭하세요
배송조회
상품명
주문번호
택배사
송장번호